Bộ điều khiển Santest GYFC2/3-Đại lý Santest tại Việt Nam

Hãng SX:
Santest
Xuất xứ:
Japan
Di động:
0914 537 669
Email:
Sale05@tmpvietnam.com
Chia sẻ:
Số lượng
Yêu cầu gọi lại
số điện thoại

Thông số kỹ thuật  Bộ điều khiển Santest GYFC2/3

Specifications

Resolution 
(position)
≦0.005%FS (*1)
≦0.01%FS (*2)
Position(OUT1)
(OUT2)
4-20mA(load:Max.500Ω)
or inverted output etc
Velocity
(option)
±10V(Resolution:1%FS)
Alarm(*3) Contact 1A 30VDC(*3)
Power supply Std:+24VDC±5%(≦350mA)
Option:±15VDC、+12VDC(*4)
Sampling freq. Std 1kHz(up to stroke 1000mm)
Temp. drift ≦±20ppmFS/°C
Operating temp. 0°C-+65°C
Storage temp. -20°C-+85°C

・The above mentioned accuracy applies to sensors with an
effective stroke of 300 mm or more.
・Zero/Gain adjustments by trimmer are possible. (STD:±3%FS)
(*1)associated probe:GYcRS, GYMR5, GYFRS
(*2)associated probe:GYcRP
(*3)Cable disconnection and magnet drop
(*4)GYcRP probe only

Model No.

①Controller type
  2:phenix connector type(STD)
  3:terminal type

②Probe
  RS:GYcRS
  RP:GYcRP
  R5:GYMR5
  FS:GYFRS
  KRS:GYKM-RS
  RPH2:GYcRP with H2 option

③Effective stroke(mm)

④Thread dead zone
  S:50mm(STD)
  □:□mm(option)(specified by customers)

⑤Associated magnet or float

magnet float
M2P :No.2P (STD)
M2PN :No.2PN
MG0 :No.Φ
M0SM :No.ΦSPM
M0LM :No.ΦLPM
M3 :No.3
M11 :No.11
M11N :No.11N
T142 :No.T14-M2
T144 :No.T14-M4
T162 :No.T16-M2
T163 :No.T16-M3
MG□ :other magnet
F28S :Φ28 SS316
F30S :Φ30 SS316L
F40S :Φ40 SS316(B)
F42S :Φ42.5 SS316
F50S :Φ50 SS316
F54S :Φ54 SS304
F25N :RF-A10 plastic
F28N :RF-A6 plastic
FL□ :other float

⑥Position output

OUT1 OUT2
AD/AR 0V-10V 10V-0V
AD/BD 0V-10V 4mA-20mA
AR/BR 10V-0V 20mA-4mA
CD05/CR05 -5V-+5V +5V--5V
CD10/CR10 -10V-+10V +10V--10V

⑦Power supply
  24S:+24VDC(STD)
  15W:±15VDC(option)(GYcRP probe only)
  12S:+12VDC(option)(GYcRP probe only)

  ±15VDC +15V(±5%)≦200mA
      -15V(±5%)≦100mA
  +12VDC +12V(±3V)≦700mA

⑧Option(blank:No option)
  Velocity output(Note1)
  V[ ]  ([ ]:Max speed(mm/sec))

  (Note1)
  ・You can specify max speed within 3%-300%/sec of effective stroke(mm).
  (ex:effective stroke=300mm, 9mm/sec-900mm/sec)

⑨Option
  X2:higher sampling freq. (double)
  <For higher sampling option>
  ・probe tip DZ needs extra 30mm
  ・for example, stroke : 500mm, standard is 1kHz and with X2 option, it is 2kHz.

Bộ điều khiển Santest GYFC2/3-Đại lý Santest tại Việt Nam

CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ TĂNG MINH PHÁT

 VPĐD: Số 1 đường 27, P. Hiệp Bình Chánh, Q. Thủ Đức, Tp.HCM

 Ðiện Thoại:  (028) 35121007                Fax: (028) 35121008

 Nhân viên kinh doanh: Nguyễn Văn Nghĩa (Mr.)

 Email:  sale05@tmpvietnam.com        Tel:  0914.537.669

 VP tại Đức: Am Boscheler Berg 4a 52134 Herzogenrath

 Website: avantgarde-x.de

Hỗ trợ

-Hỗ trợ tư vấn 24/24

-Giao hàng miễn phí tận nơi

-Bảo hành : 12 tháng

bản đồ

© 2017 Tangminhphat.com, all right reserved.

Thiết kế website www.webso.vn

Loading...

Back To Top